Getting environmental status information

The environment command enables you to display all environment information, shelf environment status, chassis environment status, and UPS devices information.

Step

  1. Enter one of the following commands:
    Command Description
    environment status Displays all storage system environment information.
    Note: For systems that contain internal drives, the environment status command displays information for both the internal and the external storage environment.
    environment status shelf [adapter] Displays the shelf environmental status for all shelves if adapter is not specified.

    You use adapter to display shelf information for shelves attached to the specified adapter.

    environment chassis Displays the environmental status of all chassis components.
    environment chassis list-sensors Displays detailed information from all chassis sensors.
    ups status Displays the status of all UPS devices.

    You can add UPS devices to be monitored, enable or disable monitoring of UPS devices, or display the status of UPS devices.