Table of ContentsLibraryView in Frames

Managing the controller module power of the storage system from the BMC

The BMC's system power command enables you to turn the power on or off or to power-cycle the storage system remotely.

Considerations

The system power cycle command automatically turns system power off and then back on. The power supplies provide a standby voltage that is always present, even when the storage system is off. This keeps the BMC running without interruption. However, turning the power off or power-cycling the storage system may cause an improper shutdown of the storage system (also called a dirty shutdown).

Steps

  1. Enter the following command at the BMC prompt: system power cycle

    Example

    bmc shell -> system power cycle
    This will cause a dirty shutdown of your appliance. Continue? [y/n]

    A warning message indicates that issuing the system power command is not a substitute for a graceful shutdown using the Data ONTAP halt command.

  2. To turn off the storage system, enter y.

    A few seconds later, the storage system is turned back on, and the boot environment prompt appears. In the meantime, the BMC prompt awaits your next command.