Restrictions for addition of disk shelves to an active/active configuration

The following table lists some of the restrictions for adding disk shelves to your active/active configuration.

See the DiskShelf14 and DiskShelf14mk2 FC Hardware Guide for a detailed discussion of restrictions.

See the System Configuration Guide for the maximum number of FC-AL adapters your storage system supports and for additional restrictions.

If your active/active configuration has… And you are… Then…
FC7 or FC8 disk shelves Adding FC9 disk shelves in the same loop Disk shelf 0 must be an FC7 disk shelf.
FC7, FC8, or FC9 disk shelves Adding DS14/DS14mk2 FC disk shelves with LRCs A DS14/DS14mk2/DS14mk4 FC must be the last disk shelf in the loop.

DS14/DS14mk2/DS14mk4 FC disk shelves with ESH, ESH2 or ESH4 modules

Hot-adding a disk shelf
  • Disks should be pre-zeroed and used as spares.
  • You can only hot-add a DS14/DS14mk2/DS14mk4 FC disk shelf to an existing DS14/DS14mk2/DS14mk4 FC disk shelf.

  • A DS14/DS14mk2/DS14mk4 FC disk shelf must be the last disk shelf in the loop.

  • DS14/DS14mk2/DS14mk4 FC disk shelves that have ESH, ESH2 or ESH4 modules can only be added to disk shelf loops that have ESH, ESH2 or ESH4 modules.

  • If the new disk shelf is a DS14/DS14mk2/DS14mk4 FC disk shelf , the loop speed switch must be set for the appropriate installation.

DS14mk2 AT disk shelves with AT-FCX modules

Hot-adding a disk shelf
  • Disks should be pre-zeroed and used as spares.
  • You can only hot-add a DS14mk2 AT disk shelf to an existing a DS14mk2 AT disk shelf.

  • a DS14mk2 AT disk shelves that have AT-FCX modules can only be added to disk shelf loops that have AT-FCX modules.