Hot-adding a disk shelf to an existing adapter in your system
Requirements for this procedure
The following requirements must be met for this procedure:
- Your system must have Data ONTAP 7.2 or later.
- There must be an available but unused adapter on your storage controller to do this procedure.
- If you have an available dual-port and an available quad-port adapter, the dual-port adapter should be used first.
- If you only have an available quad-port adapter and you are hot-adding a single loop of disk shelves, then Ports A and B are defined as a port pair and Ports C and D are defined as a port pair. For the purposes of incorporating redundancy, Module A connects to Port A or Port B and Module B connects to Port C or Port D.
Hot-adding a disk shelf to an existing adapter
To hot-add a disk shelf to an existing loop, complete the following steps.
Caution
To hot-add disk shelves to a cluster, see the cluster guide for your filer.
Copyright © 1994-2007, Network Appliance, Inc. All rights
reserved.
Part No. 210-01431_B0
File: appa5.htm
Last updated: 09-Apr-2007 17:02:50